TOUL Steristay

All the asepsis you need

TOUL Steristay– Focused laminar flow with built-in backtable is ideal to keep the surgical instruments sterile.

By using laminar operating theatres, 99.9% of airborne bacteria and micro-organisms (including Coronavirus Covid-19) are removed and surgery and prosthetic instruments are kept sterile without any time restraints, thus combating the spread of hospital, nosocomial and healthcare associated infections.

Using laminar operating theatres.

In a traditional operating room, surgical instruments are exposed to contamination, and are often the cause of infections in surgical wounds, even after years.

Using a focused laminar flow in the operating room significantly reduces the bacterial count on the instrument table, thus directly protecting the surgical and prosthetic instruments used during surgery, without any time restraints.

TOUL Steristay – Focused laminar flow with built-in backtable, it extracts the air from the operating room and filters it through a HEPA14 filtering system, removing up to 99.9% of airborne bacteria and micro-organisms (including Coronavirus SARS-CoV-2).

Toul Steristay - visualizzazione funzionamento e flusso d'aria

General features

  • the operating room laminar flow is horizontally focused to maximize its efficiency and avoid any obstacles in standard vent air flows, for optimal protection to surgical and prosthetic instruments, patients and healthcare professionals;
  • the sterile hood is traceable for defensive medicine purposes: there’s a label on the hood sterile housing and a barcode read by the device when it switches on and stored in the memory (it can also be filed);
  • TOUL Steristay complies with Standard ISO 5 even in case of intense activity, and without any time restraints. The Standard is mandatory for specialized surgeries, such as organ transplants, implants (orthopaedic, vascular, spinal, disc, urological, gynaecological), neurosurgery and oncologic surgeries, and other complex surgeries lasting more than 60 minutes.”

Technical information

Weight
57 kg
Size of the backtable supplied
130 x 60 cm
Instruments table height
80 – 120 cm
Filter
Hepa 99,995 % (H 14)
Power supply
230 V c.a., 50 Hz
Device capacity
400 m3/h
Air speed
0,5m/s
Device size
60 x 50 x 40 cm
Transport
Trolley-mounted and electrically-adjustable height

Benefits

no engineering works required for its installation

no engineering works required for its installation

horizontal air flow targeted at the instruments

horizontal air flow targeted at the instruments

easily movable trolley-mounted device

easily movable trolley-mounted device

single maintenance operations required every 2,000 hours of operation

single maintenance operations required every 2,000 hours of operation

creation of a sterile area in just a few seconds

creation of a sterile area in just a few seconds

emission of uncooled, room-temperature air

emission of uncooled, room-temperature air